EQQW007E EQQW013E
EQQW007E UNABLE TO READ WORK STATION DESCRIPTION RECORD
Explanation: The workstation description record could not be read because it may have been deleted by another
user, or an error in the workstation description database made it impossible to read the record.
System action: The system waits for you to respond.
User response: Go back to the previous panel and try again. If the error persists, contact your system programmer.
System programmer response: Contact your IBM representative.
EQQW010W THE JCC INCIDENT FILE IS NOT AVAILABLE. ERROR CODE =

ERRCODE

Explanation: The JCC incident log dataset cannot be used; error code

ERRCODE

gives the reason why. The error
codes are:
001 No incident log dataset name was defined in the JCCOPTS statement.
004 The incident log dataset could not be allocated.
005 An unrecoverable error occurred writing to the incident work file.
006 The incident log dataset could not be unallocated.
008 The incident log dataset could not be opened.
009 The incident log work dataset could not be opened.
012 An unrecoverable I/O error occurred writing to the incident log or the incident work dataset.
System action: JCC continues processing without creating any incident records.
Problem determination: Review earlier messages in the TME 10 OPC message log to determine the exact reason
for this message.
System programmer response: Correct all errors and then restart the JCC.
EQQW011I THE EVENT WRITER ENDED NORMALLY
Explanation: The event writer initialization has completed and the event writer has been requested to stop
execution.
System action: TME 10 OPC processing continues.
User response: None.
EQQW012E THE EVENT WRITER TERMINATED BECAUSE OF UNRECOVERABLE ERRORS
Explanation: The event writer initialization has completed but a severe error caused the event writer to stop
execution.
System action: The event writer terminates execution. Message EQQZ045W is issued.
Problem determination: Review earlier messages in the TME 10 OPC message log to determine the exact reason
for this message.
System programmer response: Correct all errors and then restart the event writer.
EQQW013E DISK SPACE WAS EXHAUSTED ON JCC INCIDENT FILE, DDNAME =
DDNAME
Explanation: An end-of-volume error has been detected while writing to the incident log (ddname EQQINCFI) or the
incident work (ddname EQQINCWK) dataset.
System action: If the incident log dataset is full, the JCC continues logging to the incident work dataset. If the
incident work dataset is full, the JCC issues message EQQW010W and stops writing incident log records.
System programmer response: If the incident log dataset is full, either allocate a larger dataset, or release space in
the current dataset.
If the incident work dataset is full, make sure that the JCC can allocate the incident log dataset. Empty the work
dataset by copying its contents to the incident log.
Restart the JCC to continue incident logging.
296 TME 10 OPC Messages and Codes