EQQN093E EQQN101E
EQQN093E AN SEVERE ERROR, SYSTEM ABEND
ABEND
, OCCURRED WHILE ATTEMPTING TO UPDATE THE
JOB TRACKING LOG ARCHIVE DATA SET. THE ARCHIVER TASK IS ENDING.
Explanation: An abend occurred when the JT log archiver task tried to write a log record to the job tracking archive
log data set. If the abend code is SB37 or SD37, then the archive dataset is too small.
System action: The JT log archiver task ends. The current plan updating tasks continue but if the JT log archiver
task problem is not corrected, TME 10 OPC will eventually run out of available job tracking log data sets.
Problem determination: Use the abend code to determine what is wrong with the archive data set.
TME 10 OPC administrator response: Contact your system programmer.
System programmer response: Stop TME 10 OPC. If necessary, allocate a new larger job tracking log archive
data set and copy the old data set to the new data set. After making corrections, restart TME 10 OPC.
EQQN094E AN I/O ERROR OCCURRED WHILE ATTEMPTING TO UPDATE A DUAL JOB TRACKING LOG DATA
SET. SYNAD MESSAGE FOLLOWS:
SYNMSG
Explanation: An I/O error occurred when a TME 10 OPC function tried to write a log record to the currently active
dual job tracking log file.
System action: TME 10 OPC stops logging events to the dual job tracking log data sets. Logging on the primary
job tracking log data sets continues normally.
User response: Contact your system programmer.
Problem determination: The SYNAD routine collects information such as jobname, stepname, unit address, device
type, ddname, operation, error description, and access method. The SYNADAF macro is used to extract this
information. For a detailed description of the layout refer to the appropriate documentation for the MVS/DFP product
installed on this MVS/ESA system.
System programmer response: Scratch and reallocate the failing data set at a suitable time when TME 10 OPC is
stopped.
EQQN095E A SEVERE ERROR, SYSTEM ABEND
ABEND
, OCCURRED WHILE ATTEMPTING TO UPDATE
CURRENT DUAL JOB TRACKING LOG DATA SET
Explanation: An abend occurred when an TME 10 OPC function attempted to write a record to a dual job tracking
log dataset. If the abend code is SB37 or SD37, then the current dual job tracking log dataset is too small.
System action: TME 10 OPC stops logging events to the dual job tracking log data sets. Logging on the primary
job tracking log data sets continues normally.
TME 10 OPC administrator response: Contact your system programmer.
System programmer response: If current job tracking log dataset is too small scratch the current dual log data set
and allocate a larger one at a suitable moment when TME 10 OPC is stopped.
EQQN101E THE OPC/ESA MODIFY CURRENT PLAN MODULE, EQQMCTOP, COULD NOT BE LOADED
Explanation: TME 10 OPC could not locate the modify current plan load module EQQMCTOP.
System action: NMM initialization fails.
System programmer response: Make sure that the EQQMCTOP load module is present in a library that can be
reached by TME 10 OPC, then restart the normal mode manager.
Chapter 17. EQQNnnn Messages 227