EQQ0338W EQQ0343W
EQQ0338W PRED OP ******** TO PRINT OP ******** NOT ON A CPU WS
Explanation: An automatic printer workstation operation has a predecessor on a workstation which is not an
automatic computer workstation. This is not allowed.
System action: The application in the long-term plan dataset is marked “deleted” when the current plan period is
extended. The application is not included in the new current plan or in the printed plans. The daily planning program
continues processing.
User response: Use the application description dialog to update the application description on the application
description database. And use the Modify Current Plan dialog to add the application description to the current plan.
EQQ0339W OP ******** IS NOT AN INT PRED TO PRINT OP ********
Explanation: An automatic printer workstation operation must not have an external predecessor operation.
System action: The application in the long-term plan dataset is marked “deleted” when the current plan period is
extended. The application is not included in the new current plan or in the printed plans. The daily planning program
continues processing.
User response: Use the application description dialog to update the application description on the application
description database. Use the Modify Current Plan dialog to add the application description to the current plan.
EQQ0340W PRINT OP ******** HAS NO PREDECESSORS
Explanation: An automatic printer workstation operation has no predecessors.
System action: The application in the long-term plan dataset is marked “deleted” when the current plan period is
extended. The application is not included in the new current plan or in the printed plans. The daily planning program
continues processing.
User response: Use the application description dialog to update the application description on the application
description database. Use the Modify Current Plan dialog to add the application description to the current plan.
EQQ0341W PRINT OP ******** HAS MORE THAN ONE PREDECESSOR
Explanation: An automatic printer workstation operation has more than one internal predecessor. This is not
allowed.
System action: The application in the long-term plan dataset is marked “deleted” when the current plan period is
extended. The application is not included in the new current plan or in the printed plans. The daily planning program
continues processing.
User response: Use the application description dialog to update the application description on the application
description database. Use the Modify Current Plan dialog to add the application description to the current plan.
EQQ0342W JOBNAME SHOULD BE GIVEN FOR PREP OP ********
Explanation: An operation on a workstation using the TME 10 OPC job setup facility must have a job name to
combine it with a computer operation in the same application.
System action: This application cannot be used in job tracking, and is not added to the current plan.
User response: Use the application description dialog to update the application description on the application
description database. Use the Modify Current Plan dialog to add the application description to the current plan.
EQQ0343W PREP OP ******** HAS JOBNAME ********.NO SUCC CPU OP HAS IT
Explanation: An operation on a workstation using the TME 10 OPC job setup facility must have a job name to
combine it with a computer operation in the same application. A preparation (job setup) operation is found but no
corresponding computer operation immediately succeeding it is found.
System action: This application cannot be used in job tracking, and is not added to the current plan.
User response: Use the application description dialog to update the application description on the application
description database. Use the Modify Current Plan dialog to add the application description to the current plan.