EQQW751E EQQW755W
EQQW751E THE SUBMITTOR TASK GOT
RC
IN RETURN CODE FROM THE MGCR MACRO WHEN THE STC
STCNAME
WAS ABOUT TO BE STARTED
Explanation: The submittor task cannot start this STC. The MGCR macro (SVC34) failed with the indicated return
code in register 15.
System action: The corresponding operation is set to ended-in-error with error code OSUB.
System programmer response: Contact your IBM representative.
EQQW752W A SUBMIT EVENT RECORD (TYPE I) WILL BE CREATED FOR STC
STCID
, BUT IT MAY BE TOO
LATE
Explanation: The submittor task has been restarted after ending abnormally. The abnormal termination occurred
immediately after the start command was performed for an STC, before the I event record could be created.
If more than five minutes has passed since the submittor task ended abnormally, the A1 event record is timed out.
TME 10 OPC tracking of the operation will fail.
System action: None.
User response: Check the status of the corresponding operation. Correct it manually, if necessary.
System programmer response: Investigate why the submittor task ended abnormally, and take appropriate action.
EQQW753E STC
STCID
HAS BEEN STARTED BY OPC/ESA, BUT THE MVS EXIT IEFUJI WAS NEVER OR
INCORRECTLY INVOKED. THE TRACKING WILL FAIL FOR THE STC
Explanation: The submittor task started an STC, but did not receive the expected acknowledgement from the MVS
SMF exit IEFUJI. The tracking of the STC will fail.
System action: None.
User response: Check the status of the corresponding operation. If the status is wrong, correct it manually.
System programmer response: Check that the active SMFPRM
xx
member in the SYS1.PARMLIB dataset specifies
that IEFUJI is to be invoked for STCs.
Carefully check that the IEFUJI supplied with TME 10 OPC is correctly installed.
EQQW754W THE OPC/ESA STARTED TASK FILE, DDNAME = EQQSTC, COULD NOT BE OPENED
Explanation: The submittor task failed to open EQQSTC, the started task temporary proclib file.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
Problem determination:
Save the MLOG from the TME 10 OPC subsystem.
Save the JCL from the failing job or started task.
System programmer response: Add an EQQSTC ddname to your TME 10 OPC start procedure JCL. The ddname
must specify an empty partitioned dataset.
EQQW755W THE OPC/ESA STARTED TASK FILE, DDNAME = EQQSTC, IS NOT A PDS
Explanation: EQQSTC, the started task temporary proclib file, was not allocated as a partitioned dataset.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
Problem determination:
Save the MLOG from the TME 10 OPC subsystem.
Save the JCL from the failing job or started task.
Run the AMASPZAP utility specifying ABSDUMP ALL on the dataset, and save the output.
System programmer response: Check that the dataset allocated to the EQQSTC ddname is a partitioned dataset.
320 TME 10 OPC Messages and Codes