EQQX330E EQQX333E
EQQX330E A POSITIVE RUN DAY OFFSET IS NOT BLANK OR NUMERIC 1 - 999
Explanation: The positive run day offset entered is not blank or a number from 1 to 999.
System action: The request to write the record is rejected.
Problem determination: Look in the diagnostic file (with ddname EQQDUMP) for further information. This file
contains a copy of the record and the position of the error.
User response: Enter a valid offset and if the error occurred in batch, resubmit the job. If you cannot find a valid
reason for the error, contact your system programmer.
System programmer response: Review the TME 10 OPC message log to determine the cause of the error. If you
cannot determine the cause and the error persists, contact your IBM representative.
EQQX331E THE FREE DAY SPECIFICATION

FDRULE

IS INVALID
Explanation: The free day rule entered is not E, 1, 2, 3, or 4.
System action: The request to write the record is rejected.
Problem determination: Look in the diagnostic file (with ddname EQQDUMP) for further information. This file
contains a copy of the record and the position of the error.
User response: Enter a valid free day rule and if the error occurred in batch, resubmit the job. If you cannot find a
valid reason for the error, contact your system programmer.
System programmer response: Review the TME 10 OPC message log to determine the cause of the error. If you
cannot determine the cause and the error persists, contact your IBM representative.
EQQX332E THE RUN CYCLE TYPE

NEGRC

IS INVALID. It must be N, X, R or E
Explanation: Valid run cycle types are:
NNormal offset-based run cycles
XNegative offset-based run cycles
RRegular rule-based run cycles
EException rule-based run cycles.
System action: The request to write the record is rejected.
Problem determination: Look in the diagnostic file (ddname EQQDUMP) for further information. This file contains a
copy of the record and the position of the error.
User response: Enter a valid run cycle type and if the error occurred in batch, resubmit the job.
EQQX333E THE INPUT ARRIVAL TIME
IAT
IS INVALID
Explanation: The input arrival time entered is invalid.
System action: The request to write the record is rejected.
Problem determination: Look in the diagnostic file (with ddname EQQDUMP) for further information. This file
contains a copy of the record and the position of the error.
User response: Enter a valid time and if the error occurred in batch, resubmit the job. If you cannot find a valid
reason for the error, contact your system programmer.
System programmer response: Review the TME 10 OPC message log to determine the cause of the error. If you
cannot determine the cause and the error persists, contact your IBM representative.
350 TME 10 OPC Messages and Codes