EQQZ101E EQQZ110E
EQQZ101E THE GMTOFFSET VALUE MUST BE IN THE RANGE -1439 TO +1439.
Explanation: The GMTOFFSET keyword specifies a value that is outside the range of valid values.
System action: TME 10 OPC considers current initialization statement to be incorrectly coded. This will cause
TME 10 OPC initialization to fail.
System programmer response: Correct the GMTOFFSET value and restart TME 10 OPC.
EQQZ102E THE SAME SYSTEM ID OCCURS MORE THAN ONCE IN THE SYSID KEYWORD
Explanation: The same system ID occurs more than once in the SYSID keyword of the ROUTOPTS initialization
statement. TME 10 OPC cannot determine to which system ID the DESTID should be connected.
System action: TME 10 OPC initialization fails and the subsystem ends.
System programmer response: Correct the SYSID keyword values and restart TME 10 OPC.
EQQZ103W THE SAME DESTINATION ID OCCURS MORE THAN ONCE IN THE DESTID KEYWORD
Explanation: The same destination ID occurs more than once in the DESTID keyword of the ROUTOPTS
initialization statement.
System action: TME 10 OPC processing continues.
System programmer response: Verify the SYSID and DESTID keywords, and change them if necessary.
EQQZ104E UNPAIRED NUMBER OF SYSTEM IDS AND DESTINATIONS
Explanation: The number of values in the SYSID keyword of the ROUTOPTS initialization statement does not match
the number of values in the DESTID keyword.
System action: TME 10 OPC initialization fails and the subsystem ends.
System programmer response: Change the SYSID and DESTID keywords so that they contain the same number
of values, then restart TME 10 OPC.
EQQZ106W

PERCENT

% OF QUEUE
QNAME
IN USE
Explanation: The utilization of a queue has exceeded a threshold value.
System action: None.
System programmer response: Ensure that all subtasks are active. Check system contention.
EQQZ107E TOO MANY DASD CONNECTIONS DEFINED
Explanation: You defined more than 16 destinations in the DASD keyword in the ROUTOPTS initialization
statement. At most 16 submit/release datasets can be used at the same time.
System action: TME 10 OPC initialization fails and the subsystem terminates.
TME 10 OPC administrator response: Change the DASD keyword to specify fewer destinations, then restart the
subsystem.
EQQZ110E AN XCF CONNECTION HAS BEEN SPECIFIED IN THE

OPT

STATEMENT, BUT THE XCFOPTS
INITIALIZATION STATEMENT IS MISSING
Explanation: A XCF connection cannot be established between the controller and a tracker, because the parameter
member being processed does not contain an XCFOPTS initialization statement.
The XCF connection is defined by the XCF keywords in the controller ROUTOPTS statement and the HOSTCON
keyword of the tracker TRROPTS statement.
System action: TME 10 OPC initialization terminates.
System programmer response: Add the XCFOPTS statement or change the SNA or HOSTCON keyword.
Chapter 33. EQQZnnn Messages 419