12 Functional Descriptions 07.97
12.22.2 Functional description
ACTIVATE CAM/AXIS
ASSIGNMENT DB48 DR0.6
CAM/AXIS ASSIGNMENT ACTIVATED
= DB48 DR1.6
AA
S
A -> as a function of PLC program
S -> as a function of system
S1
0
1
0
Notes:
A cam pair can be only ever be assigned to one NC axis at a time.
Several pairs of cams can be activated for one axis.
Cam signals are not output until the axes have been referenced.
Cams must not be activated until axes have been referenced.
Output of cam signals
The cam signals are transferred in the IPO cycle to the axis-specific interface DB32
DW121+m, bits 8 to 15.
12–238
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)