12 Functional Descriptions 04.96
12.25 Flexible memory configuration (SW 4 and higher)
12.25 Flexible memory configuration (SW 4 and higher)12.25.1 Corresponding data
Machine data
NC MD 60000 Size of UMS memory
NC MD 60001 Size of part program memory
NC MD 60002 Number of IKA points
NC MD 60003 Memory for drive software for MSD
NC MD 60004 Memory for drive software for FDD
NC MD 60005 Number of tools
NC MD 60006 Number of TO parameters per tool
NC MD 60007 Number of channel-specific R parameters
NC MD 60008 Number of central R parameters
NC MD 60009 Unassigned residual memory, D-RAM
NC MD 60010 Unassigned residual memory, S-RAM
NC MD 60011 NC module memory configuration
NC MD 6100* Number of block buffers in block memory in channels 1 to 6
NC MD 6200* Number of axis-specific measured values for the "Extended measurement"
function
NC MD 60013 Memory for real axes (as from SW 5)
NC MD 61020 Memory for ”Extended overstore” (as from SW 5)
to 61025
General
The "Flexible memory configuration" function allows the user to influence the memory page
allocation for:
User data
Part program data
UMS data
IKA data
R parameters
TO data
Data for real axes
Data for extended overstore
Drive software
In the case of analog drive systems, the memory space reserved for digital drive software
can be used to store user data.
Number of axis-specific measured values:
For the "Extended measurement" function.
Number of block buffers in block memory:
Depending on the capacity utilization of individual channels, it is possible to define on a
channel-specific basis the maximum permissible number of part program blocks which may
be pre-decoded during processing.
12–258
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)