Motor moment of inertia motor 1
159
Default value Lower input limit Upper input limit Units
Depends on motor 0.002 32.000 kgm2
Active on
Power On
Input of motor moment of inertia as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Motor rated power motor 1
160
Default value Lower input limit Upper input limit Units
Depends on motor 0 150.0 kW
Active on
Power On
Input of motor rated power as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Motor rated current motor 1
161
Default value Lower input limit Upper input limit Units
Depends on motor 0 200.0 A
Active on
Power On
Input of motor rated current as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Motor rated voltage motor 1
162
Default value Lower input limit Upper input limit Units
Depends on motor 0 500.0 V
Active on
Power On
Input of motor rated voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Motor rated speed motor 1
163
Default value Lower input limit Upper input limit Units
Depends on motor 0 4 096 rev/min
Active on
Power On
Input of motor rated speed as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Motor rated frequency motor 1
164
Default value Lower input limit Upper input limit Units
Depends on motor 0 409.6 Hz
Active on
Power On
Input of motor rated frequency as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50 7–19