08.96 12 Functional Descriptions
12.33.3 Current setpoint filter
Amplitude response
Magnitude
[dB]
log f [Hz]
10
2
10
3
10
3
0
-3
-10
-20
-30
Phase response
Phase
angle
log f [Hz]
10
2
10
3
180
90
0
-90
-180
150
250
0
0
150
250
Fig. 12-7 Bandstop performance with bandwidth of 500 Hz, blocking frequency of 1000 Hz
and variation in counter bandwidth of 0, 150 and 250 Hz.
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50
12–345
SINUMERIK 840C (IA)