09.95
Siemens AG 2001 All Rights Reserved 6FC5197jAA50
5–54
SINUMERIK 840C (IA)
Solution The following steps are necessary:
1. The file list of the display in which the data is to appear must be copied com-
pletely from the Siemens branch to the user branch (Services area) so that
the user semantics and user text lists are used.
Data 2007 is contained in display PLC MD/Tool management/Magazine 1
when supplied. Data list plc52.103 also belongs here.
Softkey DEFAULT under Diagnosis/Startup/PC data”.
2. Create new file
A new text list must be created in the user area under Services. This is done
by copying a text list from the Siemens area into the clipboard and giving it a
new name on execution of Insert from clipboard. This file is then edited and
the existing text is deleted.
File contents:
Only the following line is entered under the Diagnosis area:
2007 Number of assigned tool turret
All other information is then taken from the Siemens file.
3. A semantics list containing the altered input limits must be created in the user
branch.
File contents:
The following single line is enough:
2007 L 00 [ 1 , 99 ]
All other information is then taken from the Siemens file.
4. All the changes have now been made. When the display PLC MD/Tool mana-
gement/Magazine 1 is next called up, the message 106001 List display
[User/TEA2/Data lists/plc52] is being generated... will appear and the chan-
ges stored in a compressed binary file.
5. Subsequent changes could be any of the following:
a) Data lists already copied into the user branch are to be changed (e.g.
machine data sequence).
These changes are automatically observed the next time the display is
generated. Message 106001 List display [name] is being generated...”.
b) The characteristics of a data that appear in a display other than the one
already altered are to be changed.
The text required by the user is stored in a user text list and the input limits
required by the user are stored in a user semantics list.
In order to make these changes active, the data list of this additional
display must now be copied from the Siemens branch to the user branch.
Only then will the user characteristics of the data be observed. When the
display is next generated the message “106001 List display [name] is
being generated ... appears.
5 Machine Data Dialog (MDD as from SW 3)
5.10.2 Practical example for user adaptation list display