6 NC Machine Data (NC MD), NC Setting Data (NC SD) 09.95
6.3 Channel-specific MD (channel data)
Reset state G group
108*-122*
Default value Lower input limit Upper input limit Units
see below see table of input
values see table of input
values
Active in block
prior
to
decodg
The reset state for G groups 1, 3, 6, 8, 12, 15 and 25 may be defined on a channel-specific
basis.
Only those G functions shown in the table below may be specified in NC MD 108* to 122* for
the relevant G group.
The reset state for G group 9 (G70/G71) is defined together with the input resolution in
NC MD 5002.
Default valueT M G group
108* 1 1 1
110* 18 17 3
112* 54 54 6
114* 64 60 8
116* 0 0 9
118* 95 94 12
120* 150 150 15
122* 450 450 1) 25
Table of input values
Internal
G group G functions
000
MD
01
M/T
MD
10
MD 11
MD 02
MD 03
MD 33
MD 34
MD 35
MD 06
MD 12
MD 13
MD 36
MD
109
217
M
MD
18
T
MD
19
MD 16
340
M/T41 42
453
554
M/T
MD
55
MD 56
MD 57
MD
604 25 26 58 59 92 74
760
M
MD
63
MD
64
T
MD
62
MD
870 71
_______
1) As from SW 2
6–32 © Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)