6 NC Machine Data (NC MD), NC Setting Data (NC SD) 09.95
6.2 General machine data (general data)
The number of areas is specified in NC MD 210. The number of TO areas is limited to
between 1 and 4. One TO area is provided when a value of 0 is entered. If the specified value
exceeds 4, it is set to 4 internally and alarm 47 triggered.
The limits of the TO areas are defined by specifying the TO start numbers in NC MD 211 to
214. The last TO area extends from the last value specified in NC MD 211 - 214 to the
maximum tool offset number (observe NC MD 13 and 104x).
Caution!
A modification does not become effective until user memory is formatted. In "Overall Reset"
mode, user memory is formatted with the "Format User Data" or "Format TO Data" softkey.
For detailed information on invoking the "Overall Reset" mode, refer to Section General Reset.
Initial D no. for TO area 2
212
Default value Lower input limit Upper input limit Units
see below 1 809 *
Active same
as MD 210
Initial D no. for TO area 1
211
Active same
as MD 210
Initial D no. for TO area 3
213
Active same
as MD 210
Initial D no. for TO area 4
214
Active same
as MD 210
Default value: 211 = 1, 212, 213, 214 = 0
The data location numbers for TO areas 1 to 4 must be given in ascending order. Only one TO
area will be set internally and alarm 47 triggered if this rule is not observed. The TO areas are
allocated to the channels in NC MD 104*.
Example
NC MD 13
NC MD 210
NC MD 211
NC MD 212
NC MD 213
NC MD 214
Number of TO parameters
Number of TO areas
Initial D no. for TO area 1
Initial D no. for TO area 2
Initial D no. for TO area 3
Initial D no. for TO area 4
10
4
1
30
55
150
_______
*) As from SW 4 see Flexible Memory Allocation
6–20 ©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)