6 NC Machine Data (NC MD), NC Setting Data (NC SD) 09.95
6.2 General machine data (general data)
Keyswitch-protected R parameters
16, 17
Default value Lower input limit Upper input limit Units
0 0 999 *
1 299 (as from SW 4)
Active
at once
Password-protected R parameters
14, 15
Active
at once
Appropriate specifications NC MD 14/15 and/or 16/17 make it possible to protect general and
channel-specific R parameters. Channel-specific specifications apply to all channels. The
parameter area defined in MD 14-15 is password-protected, the area defined by MD 16-17 is
protected via the keyswitch. The latter is effective only when bit 3 of NC MD 5005 is "1". If
exceeded, range MD 16-17 has priority.
Zero offset group (L 960)
18
Default value Lower input limit Upper input limit Units
1 0 10 –
Active
MD 18 is of significance in conjunction with Siemens cycle L960 only, and may not be
modified.
Basic angle for nutating head
20
Default value Lower input limit Upper input limit Units
0 0 ±180 000 10-3 deg
Active
in n. block
Please observe NC MD 5010 (5D tool length compensation).
Number of buffer pairs CP 315-1
24
Default value Lower input limit Upper input limit Units
16 1 16 –
Active on
Power On
Number of buffer pairs CP 231-A
23
Active on
Power On
Number of buffer pairs CP 315-2
25
Active on
Power On
See Computer Link for details.
AP useful data length for CP 315-11-16
27
Default value Lower input limit Upper input limit Units
234 0 256
254 (as from SW 4) characters
Active on
Power On
AP useful data length for CP 231
26
Active on
Power On
AP useful data length for CP 315-2
28
Active on
Power On
See Computer Link for details.
_______
1) As from SW 4 see Flexible Memory Allocation
6–14 © Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)