7 Drive Machine Data (SIMODRIVE Drive MD) 10.94
7.1.2 MSD MD (data description - SW 3)
Input of shift factor DAC1 for analog output. The top 8 bits from a 16-bit wide memory location
are output. This machine data specifies how often the value must be shifted to the left
beforehand. A shift by one position corresponds to a multiplication by 2, i.e. the shift factor
allows multiplication by the power of two 2shift factor. The maximum gain which can be obtained
in this way is 32768 (only the last bit is evaluated).
Offset DAC1
80
Default value Lower input limit Upper input limit Units
0000 FF80 007F Hex
Active
at once
Note:
This machine data is not included in the machine data lists. The DACs are configured in the
course of the drive servo start-up procedure for diagnostic purposes.
Input of an offset value for DAC1 which is added to the value prior to analog output.
Power section code number
95
Default value Lower input limit Upper input limit Units
7 6 12 –
Active
Power On
Note:
This machine data is not included in the machine data lists. During start-up in machine data
dialog, the machine data is set or altered as appropriate via the configuration setting.
Input of code number for the power section used.
Converter table:
Code number Power section order no. Current
6 6SN1135-1DA1 -0CA0 24/32/32A
7 6SN1135-1DA1 -0DA0 30/40/51A
8 6SN1135-1DA1 -0GA0 45/60/76A
9 6SN1135-1DA1 -0EA0 60/80/102A
10 6SN1135-1DA1 -0FA0 85/110/127A
7–12 © Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)