04.96 7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
MD No. Motor 2 Title MD No. Motor 1
2132 Motor rated voltage 1132
2134 Motor rated frequency 1134
2135 Motor no-load voltage 1135
2136 Motor no-load current 1136
2137 Stator resistance cold 1137
2138 Rotor resistance cold 1138
2139 Stator leakage reactance 1139
2140 Rotor leakage reactance 1140
2141 Magnetizing reactance 1141
2142 Speed at start of field weakening 1142
2143 Upper speed Lh characteristic 1143
2144 Gain factor Lh characteristic 1144
2145 Breakdown torque reduction factor 1145
2146 Motor maximum speed 1146
2147 Speed limitation 1147
2150 P-gain flux controller 1150
2151 Integral-action time flux controller 1151
2160 Speed for start of flux detection 1160
2191 Adaptation servo limit torque 1191
2230 1st torque limiting value 1230
2231 2nd torque limiting value 1231
2232 Switching speed from Md1 to Md2 1232
2233 Generative limitation 1233
2234 Hysteresis P: 1232 1234
2235 1st power limit value 1235
2236 2nd power limit value 1236
2238 Current limit 1238
2239 Torque limit setup mode 1239
2245 Threshold speed M. setp. smoothing 1245
2246 Hysteresis speed M. setp. smoothing 1246
2400 Motor rated speed 1400
2401 Maximum motor operational speed 1401
2403 Creep speed pulse suppression 1403
2405 Monitoring speed motor 1405
2407 P-gain speed controller 1407
2408 P-gain upper adaptation speed 1408
2409 Integral-action time speed controller 1409
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50 7–165
SINUMERIK 840C (IA)