7 Drive Machine Data (SIMODRIVE Drive MD) 12.93
7.1.2 MSD MD (data description - SW 3)
Shift factor signal 2
216
Default value Lower input limit Upper input limit Units
0 0 15 –
Active
at once
Input of shift factor for signal 2 (see also MD 206). The top 8 bits from a 16-bit wide memory
location are output. This machine data specifies how often the value must be shifted to the left
beforehand.
Trigger signal value 1
217
Default value Lower input limit Upper input limit Units
0000 0000 FFFF Hex
Active
at once
Input of low amplitude for the trigger signal value (see also MD 206).
A 1 ms long trigger signal can be output on commencement of the analog output.
Trigger signal value 2
218
Default value Lower input limit Upper input limit Units
7FFF 0000 FFFF Hex
Active
at once
Input of high amplitude for the trigger signal value (see also MD 206).
A 1 ms long trigger signal can be output on commencement of the analog output.
Motor moment of inertia motor 2
219
Default value Lower input limit Upper input limit Units
Depends on motor 0.002 32.000 kgm2
Active on
Power On
Input of motor moment of inertia as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor rated power motor 2
220
Default value Lower input limit Upper input limit Units
Depends on motor 0 150.0 kW
Active on
Power On
Input of motor rated current as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor rated current motor 2
221
Default value Lower input limit Upper input limit Units
Depends on motor 0 200.0 A
Active on
Power On
Input of motor rated power as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).