04.96 7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
cos power factor
1129
Default value Lower input limit Upper input limit Units
0.8 0.0 1.0
Active on
Power On
cos is required for the calculation of the equivalent circuit diagrams from the data on the
rating plate.
Note:
This machine data only applies to main spindle drives.
Motor rated power
1130
Default value Lower input limit Upper input limit Units
0.0 0.0 1 500.0 kW
Active on
Power On
Input of motor rated power as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Note:
This data is relevant only for MSD drives.
Motor rated voltage
1132
Default value Lower input limit Upper input limit Units
380.0 0.0 5 000.0 V
Active on
Power On
Input of motor rated voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Motor rated frequency
1134
Default value Lower input limit Upper input limit Units
50.0 0.0 3 000.0 Hz
Active on
Power On
Input of motor rated frequency as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Note:
This data is relevant only for MSD drives.
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50 7–93