09.95 12 Functional Descriptions
12.19.2 Activation
Activation of IKA Stage 2
The option IKA Stage 2 applies from SW 4 and contains the IKA option. With IKA Stage 2 it is
possible not only to implement compensations but also any (non-linear) interpolations.
The options for presetting the input and output quantity have been expanded in IKA Stage 2 for
use with interpolation.
An input can be:
Axis setpoint position
Axis actual position
R parameters
An output can be:
Axis setpoint position
Axis compensation value
R parameters
Feed weighting
Since it is now possible to parameterize R parameters for both input quantities and output
quantities, the user is able to cascade IKA tables (see following diagram).
Example of cascaded IKA link branches
Axis setpnt.
position U
Axis setpnt.
position X
IKA
Input quantity A
Input quantity B
IKA configuration IKA3
with control curve 1
IKA configuration IKA4
with control curve 2
FM[Z]
(e.g. R100)
IKA
Output qty=input qty A
Input quantity B (R101)
(weighting factor)
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50
12–183
SINUMERIK 840C (IA)