6 NC Machine Data (NC MD), NC Setting Data (NC SD) 12.93
6.6.1 General MD bits (general bits)
7 6 5 4 3 2 1 0
Bit No.
NC MD
5060
5061
5062
to
5069
G function for transformation selection (1st block)
Axis name (1st block)
Transformation channel number (1st block)
Default values MD 5060, 5061: All bits default to 0
" MD 5062 to 5069: All bits default to 1
MD for 1st TRANSFORMATION BLOCK.
MD 5060 Channel numbers 1 to 4
Example for channel 3 0000 0011
MD 5061 G function for Transmit G131 0001 0001
G231 0010 0001
G331 0011 0001
MD 5062-5069 Axis name according to code table, see MD 568*
The default values must be retained if Transformation (option 6FC5 150-0AD04-0AA0) is not
used. Illegal MD results in alarm 3087.
Active: All Transmit MDs become active on Power On or on a warm restart
For a detailed description, see Section 13.4.
7 6 5 4 3 2 1 0
Bit No.
NC MD
5070
5071
5072
to
5079
G function for transformation selection (2nd block)
Axis name (2nd block)
Transformation channel number (2nd block)
See MD 5060
MD for 2nd TRANSFORMATION BLOCK.
6–112 ©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)