07.97 6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.10 MDs for flexible memory configuration
6.10 MDs for flexible memory configuration
Size of UMS memory 1)
60000
Default value Lower input limit Upper input limit Units
256 KB 0 960 or 2 760 KB
2 760 KB (as from
SW 4.4) 4 KB/8 KB
Active
after SK
"Reconfigure
memory"
With the introduction of this MD it is no longer necessary to define the UMS size in the
configuration file in the MMC master control.
The upper input limit depends on the NCK memory capacity (4 or 8 MB memory).
Zero means no UMS (see functional description of "Flexible memory configuration").
Size of part program memory 1)
60001
Default value Lower input limit Upper input limit Units
704 KB 8 960 or 2 760 KB
4 920 KB (as from
SW 4.4) 4 KB
Active
after SK
"Reconfigure
memory"
The upper input limit depends on the NCK memory capacity (4 or 8 MB memory).
Number of IKA points 1)
60002
Default value Lower input limit Upper input limit Units
4 000 0
065 535 1 IKA point
Active
after SK
"Reconfigure
memory"
Zero means no IKA points.
Memory for drive software MSD 1)
60003
Default value Lower input limit Upper input limit Units
0 0 1 –
Active
after SK
"Reconfigure
memory"
If an area of the memory is reserved for MSD drive software, 194 KB memory is occupied.
Zero means no memory.
The memory is only required for digital drives. The software only loads the MSD software if the
memory has been reserved for it.
Note:
The meaning of this machine data changes as from SW 6.
_______
1) As from SW 4
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50 6–211
SINUMERIK 840C (IA)