6 NC Machine Data (NC MD), NC Setting Data (NC SD) 04.96
6.9 MDs for parameter set switchover
Emergency retraction threshold 2nd - 8th parameter as
from SW 4
2560*-2566*
Default value Lower input limit Upper input limit Units
400 0 16 000
99 999 999 (SW5.4
and higher) 1 unit (MS)
Active on
RESET
These MD have the same meaning as MD 493*, see also ”Functional Descriptions: Parameter
set switchover”.
Time const. speed link path 1st to 8th par. set
as from SW 4
2567*-2574*
Default value Lower input limit Upper input limit Units
0 0 16 000 0.1 ms
Active on
NC Stop
These machine data are active only with gear interpolation.
Master for speed setpoint coupling
1)
2700*
Default value Lower input limit Upper input limit Units
0 0 50 -
Active on
Power On
Machine data 2700* assigns the master spindle to a slave for speed setpoint coupling. The
speed setpoint is taken from the spindle entered here and output as the speed setpoint while
ignoring its own position control. The assignment is made with the axis/spindle number.
Value 0 1 - 30 41 - 46
Meaning No axis/spindle Axis 1 - 30 Spindle 1 - 6
Master for torque compensation control
1)
2701*
Default value Lower input limit Upper input limit Units
0 0 50 -
Active on
Power On
Machine data 2701* assigns the master spindle to a slave. The torque setpoint is taken from
the spindle entered here and compared with the torque setpoint of its own drive. The
difference is the input variable for the torque compensation controller.
The assignment is made via the axis/spindle number.
If the default value 0 is entered, the master of the speed setpoint coupling (MD 270*) is also
used for the torque compensation control.
Value 0 1 - 30 41 - 46
Meaning No axis/spindle Axis 1 - 30 Spindle 1 - 6
_______
1) As from SW 4.4
6–200 ©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50