Configur.
mixed I/O
09.95
Siemens AG 2001 All Rights Reserved 6FC5197jAA50 9–35
SINUMERIK 840C (IA)
Lower input limit Upper input limit
SERVO (SW 3 SW 4) –7 31
FDD (SW 3/SW 4) –7 23
MSD (SW 3) 0 15
MSD (SW 4) –7 23
Notes Make sure that the selected drive (display) corresponds to the connected test
sockets (DACs) of the appropriate drive (module) in the case of 611D signals.
Servo signals (max. 4) can be output by every module however, the axis name
must also be input.
The analog output must be set again after power on reset.
When 611D signals are output from an
SFDD (speed/current controller signals) or an
SMSD (speed SW 4: current controller/signals)
the drive (drive number) which is to be measured must be selected for the output.
The “Axis/spindle” input field has no function in this case.
Note SIt is not possible to save the DAC configuration with Load/save all for com-
plete backup, nor is it possible to load a boot file via the File function.
SThe DAC boot file should be deleted if the DACs are not longer required, in
order to reduce the load on the processor.
SIt is no longer possible to reinstall the analog output after Power On as these
DACs are active again after Power On.
Fig. 9.15
9 Drive Servo Start-Up Application (as from SW 3)
9.4 Mixed I/O configuration and digital-analog converter, DAC (as from SW 3)