Measurement
Start
Stop
09.95
Siemens AG 2001 All Rights Reserved 6FC5197jAA50

9–40

SINUMERIK 840C (IA)
Fig. 9.16
Explanation The axis names with which the circle is to be traversed are selected in this dis-
play. No check is made to ascertain whether the selected axes correspond to
those programmed in the part program.
The measurement time for the circularity test can be parameterized only by
means of radius and feedrate and is displayed when the measurement com-
mences or when softkey Measurement is selected again.
The values entered in input fields Radius and Feed must correspond to those
entered in the part program controlling the circular motion of the axes, with allow-
ance made for the override switch. No check is made to ascertain whether the
values in the part program (including override) correspond to those entered in the
display.
Display field Meas. time displays the measurement time required to record the
position actual values during traversal of the circle; this time is calculated on the
basis of the radius and feed values.
It is also possible to parameterize the mode in which measurement results are
represented (via programmed radius or mean radius) and the resolution (scaling
of diagram axes). These inputs are used by the MMC to prepare representation
of the measured values in the form of a circle diagram.
If the measurement time exceeds the time range which can be represented by
the trace buffers (measurement time position controller cycle x 2048), then an
appropriate sub-scanning process is executed for the recording.
The user must start the test program chosen to control the traversing motion (cir-
cular) for the selected axes by means of NC start to ensure that the program
receives the values required to perform the measurement function. NC start can
be executed from standard operating modes such as MDA or AUTOMATIC.
SThe measurement function is initiated by selecting the vertical Start softkey.
SThe measurement can be terminated at any time by selecting the vertical
Stop softkey.
9 Drive Servo Start-Up Application (as from SW 3)
9.5.2 Circularity test (option SW 4)