09.95 6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.2 General machine data (general data)
Error window for repositioning on circle contour
9
Default value Lower input limit Upper input limit Units
200 +0 32 000 units (IS)
Active in
next block
An automatic interruption during circular contouring (G2/G3) results in departure from the
contour in JOG mode.
Prior to a new NC start, the contour must be reapproached in JOG mode.
If the axis is not within the tolerance limits (shaded area) specified in NC MD 9 following the
NC start, alarm 3018 is displayed and the program is not started.
A B
MD 9 or path ”S”
MD 9 or path ”S”
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50 6–11
SINUMERIK 840C (IA)