09.95
Siemens AG 2001 All Rights Reserved 6FC5197jAA50
4–26
SINUMERIK 840C (IA)
4.4.2.1 Keywords
Keywords are words reserved by the system.
The following keywords exist:
SLANGUAGE Language set for NCK and MMC
SLANGUAGE1 Language set for WOP 3)
SLANGUAGE2 Language set for simulation 3)
SLANGUAGE3 Language set for PG function 3)
SLANGUAGE4 Language set for user 3)
SBT_NAME FlexOS name of the operator panel interface
SBT_PARAM Name “”; operation without operator panel
SPROTLEN1 Size of the alarm log in number of messages
SPROTLEN2 Size of the service log in number of messages
SFLUSHLEN1 Maximum number of messages buffered for the alarm log
SFLUSHLEN 2 Maximum number of messages buffered for the service log
SFLUSHTIME Maximum buffering time for messages in milliseconds
SPROTMASK1 Type of messages to be entered in the alarm log 1)
SPROTMASK2 Type of messages to be entered in the service log
SPRIO_PO Display priority of NCK alarms with alarm type power on1)
SPRIO_RE Display priority of NCK alarms with alarm type reset1)
SPRIO_CA Display priority of NCK alarms with alarm type cancel1)
SPRIO_PA Display priority of PLC alarms 1)
SPRIO_PM Display priority of PLC messages 1)
SPRIO_KO Display priority of NCK comments 1)
SSYSFONT Defines the character set in the configuration file of the
master control 2)
STFORMAT Format in which the times are to be written to the log
4 MMC Area Diagnosis
4.4.2 Configuration file CONFIG
1) Up to SW 2 only
2) SW 4.4 and higher
3) SW 5 and higher