12 Functional Descriptions 07.97
12.25.4 Memory configuration on control power-up
Fig. 3
Machine Parameter Program. Services Diagnosis
Start-up/machine data/NC MD/memory configuration
DRAM
data SRAM
data Reconfig.
memory File
functions
DRAM memory configuration
Number of meas. value buffers
62000 Axis 1 0 at 4 B
62001 Axis 2 0 at 4 B
62002 Axis 3 0 at 4 B
62003 Axis 4 0 at 4 B
:: :
:: :
:: :
:: :
62028 Axis 29 0 at 4 B
62029 Axis 30 0 at 4 B
Free remaining memory - DRAM data: 0 bytes
Free remaining memory - SRAM data:
Find
ncmemcfg
Fig. 4
Machine Parameter Program. Services Diagnosis
Start-up/machine data/NC MD/memory configuration
DRAM
data SRAM
data Reconfig.
memory File
functions
Find
SRAM memory configuration
General data II
60005 Number of tools 819 at 4 B
60006 Number of parameters per tool 10 at 4 B
60007 No. of chan.-specific R parameters 700 at 4 B
60008 Number central R parameters 600 at 4 B
Free remaining memory - DRAM data: 29 772 bytes
Free remaining memory - SRAM data: 13 552 bytes
ncmemcfg
Note:
Changes of the SRAM memory configuration require execution of
"Format user data"!
12–264
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)