7 Drive Machine Data (SIMODRIVE Drive MD) 07.97
7.3.2 Drive MD (data description)
Format of power section code number:
Value table:
Code Drive type Current PS Comments
6 MSD 24/32/32 A 50 A
7 MSD 30/40/51 A 80 A
8 MSD 45/60/76 A 120 A
9 MSD 60/80/102 A 160 A
A MSD 85/110/127 A 200 A
B MSD 120/150/193 A 300 A
C MSD 200/250/257 A 400 A
D MSD 45/60/76 A 108 A
11 FDD 3/6 A 8 A
12 FDD 5/10 A 15 A
14 FDD 9/18 A 25 A
16 FDD 18/36 A 50 A
17 FDD 28/56 A 80 A
19 FDD 56/112 A 160 A
1A FDD 70/140 A 200 A
28 FDD 140/210 A 400 A as from SW 4.1
Transistor limit current, power section
1107
Default value Lower input limit Upper input limit Units
200.0 1.0 500.0 A
Active on
Power On
Input of maximum permissible current of power section. This machine data is automatically
parameterized for Siemens power sections by the machine data "Power section code"
(MD 1106).
Caution:
This data serves as the basis for normalizing the current actual value sensor and must not be
changed by the user after automatic presetting of its values.
7–88 © Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)