7 Drive Machine Data (SIMODRIVE Drive MD) 07.97
7.3.2 Drive MD (data description)
Note regarding bit 9:
Incorrect parameterization, e.g. not on EQN MD 1011 (configuration actual-value acquisition,
indirect measuring system)
or MD 1030 (configuration actual-value acquisition, direct measuring system)
or obsolete hardware (not suitable for EQN)
or no encoder connected
or incorrect encoder cable (for ERN instead of for EQN).
Configuration actual-value acquisition, direct measuring
system
1030
Default value Lower input limit Upper input limit Units
0000 0000 FFF Hex
Active on
Power On
Input of the configuration for actual-value functions with reference to the SIMODRIVE system
611D, direct measuring system.
Bit 0 - 2 Not assigned
Bit 3 Encoder type 0= incremental encoder
1= absolute encoder with EnDat
interface
Bit 4 Design of the measuring system 0= rotary measuring system
1= linear measuring system
Bits 5-13 Not assigned
Bits 14-15 Transmission rate EnDat encoder 00= 100 kHz
01= 500 kHz
10= 10 kHz
11= 2 kHz
Multiturn resolution absolute encoder direct measuring
system
1031
Default value Lower input limit Upper input limit Units
4096 0000 65535 rev
Active on
Power On
Number of revolutions of the absolute encoder, direct measuring system, that can be
represented. The value can only be read.
Measuring increments of the absolute track, direct
measuring system
1032
Default value Lower input limit Upper input limit Units
8192 0 8 388 607 Incr/rev
Active on
Power On
The number of measuring increments per revolution for serial transmission of the absolute
position value, direct measuring system. The value can only be read.
7–80 © Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)