7 Drive Machine Data (SIMODRIVE Drive MD) 10.94
7.1.2 MSD MD (data description - SW 3)
Motor code number motor 2
238
Default value Lower input limit Upper input limit Units
101 99 332
Active on
Power On
Note:
This machine data is not included in the machine data lists. During start-up in machine data
dialog, the machine data is set or altered as appropriate via the configuration setting.
Input of code number for the motor used. The relevant motor data are stored in the software
and are transferred to machine data MD 219 to MD 235 when the motor code number is
changed. If individual motor data (MD 219 to MD 235) must be changed, then the value 99
(non-Siemens motor) must be entered as the motor code number.
See machine data MD 96 for table of motors.
Programmable message 1
241
Default value Lower input limit Upper input limit Units
2 1 20 –
Active
at once
A function can be assigned to programmable message 1 in this machine data. The range of
available functions is listed in the table below.
The default setting corresponds to Ramp-up complete.
Table of functions:
Function Function number
(setting value of
MD 241 ... MD 246)
Default setting of
MD 241 ... MD 246
| nact | < nmin
1 MD 243
Ramp-up complete 2 MD 241
| Md | < Mdx 3 MD 242
| nact | < nx 4 MD 244
Motor overtemperature
prewarning 5 --
Heat sink overtemperature
prewarning 6 --
Variable relay function 1
(MD 185 - MD 189) 7 MD 246
Variable relay function 2
(MD 190 - MD 194) 8 --
nact = nset 20 MD 245
7–34 © Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)