12.93 7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
Speed at start of field weakening motor 2
233
Default value Lower input limit Upper input limit Units
Depends on motor 100 6 000 rev/min
Active on
Power On
Input of speed at which field weakening starts as specified on the motor data sheet (non-
Siemens motor) or automatic parameterization using machine data "Motor code number" (MD
238). In the field-weakening range, the magnetizing reactance Xh increases linearly from the
saturated value at the speed at which field weakening begins to the unsaturated value at the
upper limit speed of the Xh characteristic (see diagram MD 175).
Motor maximum speed motor 2
234
Default value Lower input limit Upper input limit Units
Depends on motor 0 20 000 rev/min
Active on
Power On
Input of motor maximum speed as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Gain factor Xh-characteristic motor 2
235
Default value Lower input limit Upper input limit Units
Depends on motor 100 300 %
Active on
Power On
Input of gain factor (Xh2/Xh1) of the Xh characteristic (magnetizing reactance) as specified on
the motor data sheet (non-Siemens motor) or automatic parameterization using machine data
"Motor code number" (MD 238). In the field-weakening range, the magnetizing reactance Xh
increases linearly from the saturated value at the speed at which field weakening begins to the
unsaturated value at the upper limit speed of the Xh characteristic (see diagram MD 175).
Note:
If the value is unknown, then 100 % must be entered in order to obtain constant magnetizing
reactance over the entire speed range.
Breakdown torque reduction factor motor 2
236
Default value Lower input limit Upper input limit Units
100 1 150 %
Active
at once
Input of breakdown torque reduction factor as specified on the motor data sheet. The point at
which the breakdown torque limit is applied can be altered in this machine data.
Settings of higher than 100 % increase the point at which the limit is applied and vice versa
with settings of lower than 100 %.
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50 7–33
SINUMERIK 840C (IA)