7 Drive Machine Data (SIMODRIVE Drive MD) 10.94
7.1.2 MSD MD (data description - SW 3)
Minimum value min/max memory
182
Default value Lower output limit Upper output limit Units
– 0000 – Hex
Active
at once
Output of minimum value of a previously defined variable (see MD 181). The value is displayed
in hexadecimal format.
Maximum value min/max memory
183
Default value Lower output limit Upper output limit Units
– 0000 – Hex
Active
at once
Output of maximum value of a previously defined variable (see MD 181). The value is
displayed in hexadecimal format.
Address for monitoring 1
185
Default value Lower input limit Upper input limit Units
0C06 0000 FFFF Hex
Active
at once
Input of address 1 to be monitored for variable relay function 1.
Threshold for monitoring 1
186
Default value Lower input limit Upper input limit Units
0000 0000 FFFF Hex
Active
at once
Input of threshold value 1 of address 1 to be monitored for variable relay function 1.
ON-delay monitoring 1
187
Default value Lower input limit Upper input limit Units
0 0 10.00 s
Active
at once
Input of ON-delay 1 of address 1 to be monitored for variable relay function 1.
Drop delay monitoring 1
188
Default value Lower input limit Upper input limit Units
0 0 10.00 s
Active
at once
Input of drop delay 1 of address 1 to be monitored for variable relay function 1.
7–24 © Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)