09.01 12 Functional Descriptions
12.19.5 Interpolation and compensation with tables
Data type Significance Data No.
within data
type
Data type
for
@30c/40c
or T para.
G fct. for
IKA G fct. for
CGI Only valid
with IKA
Stage 2
Weighting input A
(denominator) 1 to 32 19
-
Function not
available x
Input B (number) 1 to 32 25 G411 Function not
available x
Input B (type) 1 to 32 26 G411 Function not
available x
Output (number) 1 to 32 3 G411 G401
Output (type) 1 to 32 33 G411 G401
Weighting factor
output (numerator) 1 to 32 4 G412 G402/G403
Weighting factor
output (denominator) 1 to 32 30 G412 G402/G403 x
Max. output value
upper limit (not for
compensation)
1 to 32 31
--
x
Unit
EGF Min. output value
lower limit (not for
compensation)
1 to 32 32
--
x
EGF Max. change of
output value (not for
compensation)
1 to 32 34
--
x
Unit
Value x EGF
IPO
Internal status of
IKA (see following
table)
37
--
x
Value actual input A 1 to 32 21
--
x
Table input value 1 to 32 22
--
x
Value actual input B 1 to 32 27
--
x
Actual output value 1 to 32 35
--
x
Interpolat. point no. 1 to 32 36
--
x
Actual switching
state 1 to 32 37
--
x
%IKA1 IKA
configuration
Type definition of data type 37 "Internal condition of IKA":
Final conditions of IKA:
0: IKA deactivated
1: IKA deactivated
2: IKA deactivated in plus direction
3: IKA deactivated in minus direction
Intermediate conditions of IKA during transition to a new final condition:
4: IKA is deactivated
5: IKA is activated and deactivated
6: IKA is switched over
7: IKA is deactivated position-dependently
8: IKA is deactivated position-dependently in plus direction
9: IKA is deactivated position-dependently in minus direction
10: IKA is switched on and over position-dependently
11: IKA is switched on and over position-dependently in the plus direction
12: IKA is switched on and over position-dependently in the minus direction
13: IKA is switched over position-dependently
14: IKA is switched over position-dependently in the plus direction
15: IKA is switched over position-dependently in the minus direction
16: IKA is stopped
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50
12–203