12.93 6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.12.1 NC setting data (NC SD)
Scale centre NC
312*
Default value Lower input limit Upper input limit Units
0 – 99 999.999 + 99 999.999 mm or inches
Active on
The scale centre defines where the reference point for the alteration of the programmed axis
positions using the scale factor lies (see Programming Guide for detailed description).
The scale centre is programmed together with G51 in the block.
Clamping torque for move against fixed stop
320*
Default value Lower input limit Upper input limit Units
0 1 999 0.1 %
Active on
This SD is used to define the desired clamping torque as a % of the max. torque of the
component. Input in units of 0.1 %
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
6–225
SINUMERIK 840C (IA)