6 NC Machine Data (NC MD), NC Setting Data (NC SD) 09.95
6.9 MDs for parameter set switchover
Number of teeth motor
2)
1st par. set to 8th par. set
3032*-3060*
Default value Lower input limit Upper input limit Units
11 999 999
99 999 999 (as from SW 4.4)
Active on
Power On
Number of teeth spindle
2)
1st par. set to 8th par. set
3064*-3092*
Default value Lower input limit Upper input limit Units
11 999 999
99 999 999 (as from SW 4.4)
Active on
Power On
This machine data is used to define the speed ratio of a gear box for all parameter sets, see
functional description of "”Ratio” parameter group".
Zero mark correction +
2)
1st par. set to 8th par. set
3096*-3124*
Default value Lower input limit Upper input limit Units
0- 999 999
16 000 (as from SW 4.4) 999 999
16 000 (as from SW 4.4) units (MS)
Active on
NC Stop
Zero mark correction -
2)
1st par. set to 8th par. set
3128*-3156*
Default value Lower input limit Upper input limit Units
0- 999 999
16 000 (as from SW 4.4) 999 999
16 000 (as from SW 4.4) units (MS)
Active on
NC Stop
These MDs are used to correct gear-stage-related offsets between the zero mark and
reference position, see functional description of "”Ratio” parameter group".
Backlash comp. 1st measuring system
2)
2nd par. set to
8th par. set
3160*-3184*
Default value Lower input limit Upper input limit Units
0 - 16 000 16 000 units (MS)
Active on
NC Stop
For axes only:
To compensate for the backlash in different gear stages.
Motor control equilibration 2nd - 8th par. set
as from SW 4
3188*-3212*
Default value Lower input limit Upper input limit Units
0-70
-700 (as from SW 4.4) 70
-700 (as from SW 4.4) 0.1 % of the power
section current
Active on
NC Stop
These MD have the same meaning as MD 1292*, see also ”Functional Descriptions:
Parameter set switchover”.
_______
1) As from SW 4.4
2) As from SW 4
6–202 ©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)