10 Axis and Spindle Installation 03.95
10.2.5 Permissible resolution combinations
10.2.5 Permissible resolution combinations
Permissible resolution combinations
Input resolution, display resolution and position control resolution can be defined in any
combination within certain limits (see the following two tables). Please note that a factor of
max. 200 between input resolution and position control resolution for all axes together is
possible.
Example: Input resolution 10-4 mm or degrees
Position control resolution rotary axis 0.5 . 10-4 degrees
Position control resolution machining axes 0.5 . 10-3 mm
Position control resolution loader axes 0.5 . 10-2 mm
Permissible combinations of position control resolution and input resolution
Unit
system
Position control
resolution
Input resolution
10-2
[mm]
[degr.]
10-3
[mm]
[degr.]
10-4
[mm]
[degr.]
10-5
[mm]
[degr.]
10-3
[inch]
[degr.]
10-4
[inch]
[degr.]
10-5
[inch]
[degr.]
10-6
[inch]
[degr.]
mm 0.5 x 10-2
[mm][degr.] xy x x
-
x x x
-
mm 0.5 x 10-3
[mm][degr.] xy xy 2) x
-
x x x
-
mm 2 x 10-4
[mm] x x x x
- -
x x
mm 0.5 x 10-4
[mm][degr.] xy xy xy x
- -
x x
mm 0.5 x 10-5
[degr.] y y y y
- - - -
inch 0.5 x 10-3
[inch][degr.] x x
- -
xy x x
-
inch 0.5 x 10-4 [inch][degr.] x x
- -
xy xy x
-
inch 2 x 10-5
[inch] xxxxxxxx
inch 0.5 x 10-5
[inch][degr.] x x x x xy xy xy x
x ... linear axes only
y ... rotary axes only
xy ... linear and rotary axes
... linear and rotary axes illegal
2) standard machine data
Note:
Excessive differences between position control resolution and input resolution ought to be
avoided. For example, an input resolution of 10-2 mm together with a position control resolution
of 0.5 - 10-5 mm does not make sense since one geometry resolution unit equals 1000
position control resolution units.
If the units of both position control and input resolution belong to the same unit system (metric,
inches, degrees), the display resolution and the position control resolution must be equal (see
table above).
If the units of the position control and input resolution do not belong to the same unit system,
the display resolution must be set according to the table above.
As a matter of principle, the same unit system must be used for the display resolution and the
input resolution.
Note:
As from SW 4, the position control and display resolution for the rotary axes must not exceed
the input resolution.
_______
1) Bit "High-resolution rotary axis" must be set for rotary axes. For input resolution 10
-4
, otherwise alarm
message 4 "System of units illegal" is output.
10–8 © Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)