09.95
Siemens AG 2001 All Rights Reserved 6FC5197jAA50

5–10

SINUMERIK 840C (IA)
Spindle
SMode group:
The assignment of mode group to spindle is determined by the setting in NC
MD 4530 ff (spindle valid in mode group).
SAvailable:
The spindle is displayed as existing when NC MD 5210.7 ff (spindle exists) is
set.
Axis No.
SMode group:
The assignment of mode group to axis no. is determined by the setting in NC
MD 3600 ff (axis no. valid in mode group).
SName
The name of the axis appears in this window when NC MD 5680 ff (axis
name) is set.
Possible inputs are: XX15, YY15, ZZ15, AA15, BB15, CC15, UU15,
V–V15, WW15, QQ15, EE15.
SAvailable:
The axis is displayed as existing when NC MD 5640.7 ff (axis exists) is set.
SAxis type:
The display tells you whether the axis is real or fictitious, as set in NC MD
5640.6 ff.
real: Input = No
fictitious: Input = Yes
SRotary axis:
The display tells you whether the axis is a linear or rotary axis, as set in NC
MD 5640.5 ff.
linear: Input = No
rotary: Input = Yes
Notes Only the channels, axes and spindles defined in the NC configuration display are
also displayed in the following displays (channel, axis, spindle MD softkeys).
You must execute a PLC cold restart via the General reset mode function if you
wish to alter the number of channels, spindles and axes.
5 Machine Data Dialog (MDD as from SW 3)
5.2.1 NC configuration