09.95
Siemens AG 2001 All Rights Reserved 6FC5197jAA50

5–34

SINUMERIK 840C (IA)
In the case of Save all the NQEC parameterization including the measured val-
ues from the NCK/servo are read out and stored in ASCII files under the selected
name.
In the case of Load all, the selected NQEC ASCII files are read in and stored as
boot files. A backup mechanism which is similar to that of TEA2-Load-all is imple-
mented which is able to recover the NQEC boot files automatically on a power
failure, emergency stop, if the hard disk is full or the abort key has been operated
etc.
New alarms for this function: 165051 to 165054.
5.8.2 2nd level: Configuring the individual machine data areas (SW 3 and higher)
Drive machine data (TEA3)
Axis
(FDD) Spindle
(MSD) File
functions
NC machine data (TEA1)
General
NC MD Geometry
motion Channel Axis Spindle Gearbox
interpol. File
functions
Memory
config. "
PLC machine data (TEA2)
I/O device
setting Alarms
messages PLC basic
data User
MD Tool
manage-
ment
Computer
link File
functions
Cycle machine data (TEA4)
Central
cycle MD Chan. dep.
cycle MD File
functions
Interpolation compensation machine data (IKA1 – IKA3)
IKA con-
figuration IKA curve
pointer IKA error
points File
functions
Explanation On the 2nd level the file functions refer to the data of the individual machine data
areas. If the same file names are assigned to data records in different areas, they
appear on the first level (machine configuration) under one data selector and can
be loaded together from there.
5 Machine Data Dialog (MDD as from SW 3)
5.8.2 2nd level: Configuring the individual machine data areas (as from SW 3)