www.ti.com

VIC Port Registers

6.5.1 VIC Control Register (VICCTL)

The VIC control register (VICCTL) is shown in Figure 6-3and described in Table 6-4.

Figure 6-3. VIC Control Register (VICCTL)

31

 

 

 

16

 

Reserved

 

 

 

 

R-0

 

 

 

15

4

3

1

0

Reserved

 

PRECISION

 

GO

R-0

 

R/W-0

 

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n= value after reset

Table 6-4. VIC Control Register (VICCTL) Field Descriptions

Bit

field

symval (1)

Value

Description

31-4

Reserved

-

0

Reserved. The reserved bit location is always read as 0. A value written to this field

 

 

 

 

has no effect.

3-1

PRECISION

OF(value)

0-7h

Precision bits determine the resolution of the interpolation. The PRECISION bits can

 

 

 

 

only be written when the GO bit is cleared to 0. If the GO bit is set to 1, a write to the

 

 

 

 

PRECISION bits does not change the bits.

 

 

DEFAULT

0

16 bits

 

 

16BITS

 

 

 

 

15BITS

1h

15 bits

 

 

14BITS

2h

14 bits

 

 

13BITS

3h

13 bits

 

 

12BITS

4h

12 bits

 

 

11BITS

5h

11 bits

 

 

10BITS

6h

10 bits

 

 

9BITS

7h

9 bits

0

GO

OF(value)

 

The GO bit can be written to at any time.

 

 

DEFAULT

0

The VICDIV and VICCTL registers can be written to without affecting the operation of

 

 

0

 

the VIC port. All the logic in the VIC port is held in reset state and a 0 is output on the

 

 

 

VCTL output line. A write to VICCTL bits as well as setting GO to 1 is allowed in a

 

 

 

 

 

 

 

 

single write operation. The VICCTL bits change and the GO bit is set, disallowing any

 

 

 

 

further changes to the VICCTL and VICDIV registers.

 

 

1

1

The VICDIV and VICCTL (except for the GO bit) registers cannot be written. If a write

 

 

 

 

is performed to the VICDIV or VICCTL registers when the GO bit is set, the values of

 

 

 

 

these registers remain unchanged. If a write is performed that clears the GO bit to 0

 

 

 

 

and changes the values of other VICCTL bits, it results in GO = 0 while keeping the

 

 

 

 

rest of the VICCTL bits unchanged. The VIC port is in its normal working mode in this

 

 

 

 

state.

(1)For CSL implementation, use the notation VIC_VICCTL_field_symval

SPRUEM1 –May 2007

VCXO Interpolated Control Port

171

Submit Documentation Feedback

Page 171
Image 171
Texas Instruments TMS320DM648 manual VIC Control Register Vicctl Field Descriptions