USER’S GUIDE

3.To correct the problem, try the following:

Error mapping adapter # into Host memory map

Type mismatch of configured & installed adapter #

a.Terminate the system software: Type: quit<return>

Check the configuration for the Serial Adapter resource. The configuration must match the resource type and hardware settings. For details, refer to the Hardware Overview and the Hardware Installation chapter.

Turn the CyberSWITCH off, then on

Press: <Power Off><Power On>

Continue with step 1 in the section Verifying WAN Line Availability (and reestablish the ad- ministration session, if necessary).

b.If this fails to correct this problem, check to see if the Serial adapter is properly installed in the system.

Serial dedicated down: Slot #, Port #

a.Check that the serial cable is properly connected to the Serial Adapter resource.

Continue with step 1 in the section Verifying WAN Line Availability (and reestablish the ad- ministration session, if necessary).

b.If this fails to correct this problem, check to see that the Serial cable is properly connected to the network termination equipment.

c.If the above actions fail to correct this problem, check that the serial adapter is configured to match the network requirements.

4.If this fails to correct the problem, the Serial adapter may be faulty. If you have a spare Serial adapter resource available, replace the faulty Serial adapter with the spare. Contact Customer Support.

CAUTION:

If at any time you need to remove the system cover, be sure to turn the system OFF and unplug it first.

LAN CONNECTION OPERATIONAL?

To verify the operation of the LAN connection, the Ethernet LAN adapter resource must already be operational:

1.Connect the CyberSWITCH to a properly terminated Ethernet LAN. Note that an external MAU (and AUI cable if needed) is required for this connection.

2.Transmit a test packet onto the Ethernet LAN. At the administration console type:

lan test <return>

422 CyberSWITCH

Page 422
Image 422
Enterasys Networks CSX7000, CSX5500, CSX6000 manual LAN Connection OPERATIONAL?