SYSTEM STATISTICS

Compression Statistics

COMPRESSION STATISTICS

The system collects the following compression statistics for each active compression connection. These statistics can be displayed by issuing the cmp stats or the cmp stats <device name> command at the administration console. The cmp stats command will display the compression statistics for all active connections. The cmp stats <device name> command will display the compression statistics for the specified device. Note that the device name is case sensitive.

Note: When using PPP, it is possible that CCP can open with no agreed upon compression algorithm in one or both directions. In such cases, the connection is considered to be running with compression, and will consequently be picked up by the CMP command. However, the ratios and counters for the direction(s) without an actual compression algorithm negotiated will not indicate any effective compression or decompression.

COMPRESSION RELATED STATISTICS

cmp ratio

The number of uncompressed bytes divided by the number of compressed bytes.

uncmp Kbytes

The total number of uncompressed kilobytes received.

cmp Kbytes

The total number of compressed kilobytes sent.

total cmp reset count

The total number of compression resets (peer and System sent resets).

peer sent resets

The number of compression resets sent from peer devices.

system sent resets

The number of decompression resets sent from the System.

dropped pkts

The number of dropped packets that could not be queued.

DECOMPRESSION RELATED STATISTICS

dmp ratio

The number of decompressed bytes divided by the number of compressed bytes.

dmp Kbytes

The total number of decompressed kilobytes sent.

cmp Kbytes

The total number of compressed kilobytes sent.

total dmp reset count

The total number of decompressed resets (peer and System sent resets).

Central Site Remote Access Switch 635