USER’S GUIDE

Network sent Cause - SPID not supported - <slot #, port # >

The indicated line does not support SPIDs; however, a SPID is configured for use on the line. Is the SPID configured incorrectly? Do you have the right switch type? Check the configuration. If the message persists, contact your BRI provider to determine corrective action.

Network sent STATUS with state = 0, tear down call

A STATUS message has been received from the network indicating that a specified call is not active. The system is removing the call.

No Active Calls

0 Active Sites

Currently, no sites are connected to the system.

No Active List entry available in INM

The system tried to contact a remote site and no table entries were available. You may need a larger version of the CyberSWITCH.

No CCB found, Port=<port #>, CallRef=<call reference #>

Contact your Distributor or Customer Support. Provide your distributor with a copy of the message log, and the output of the wan stats command. With the wan stats command, the main item of interest is the “rcv fail” number on the connections line.

No compression sessions are available due to memory constraints.

Check available memory; upgrade to a 12Mb system (minimum). If you are still encountering problems, disable unused protocols, and/or contact your Distributor or Customer Support to reduce your number of available connections.

NO FR LMI transmit buffer available

Indicates that, temporarily, no transmit buffer was available for formatting and sending a STATUS ENQUIRY message to the network.

NO FR LMI transmit buffer descriptor available

Indicates that, temporarily, no transmit buffer descriptor was available for control and administration of a STATUS ENQUIRY message to be sent to the network.

No internal b channel resources available, disconnecting call

The call is up, but there are no resources available to send the data. Contact your Distributor or Customer Support.

No resources available to accept incoming call

The System received an incoming call, but it had already established the maximum number of calls. This indicates the demand for network resources exceeds the configuration of this system. If this type of occurrence continues, you should consider upgrading to a larger system.

No response received from caller to our callback request. Terminating Call.

A modem connection negotiated callback, the CyberSWITCH sent a callback request to the caller (the PC) but got no response. Make sure the caller entered a callback phone number when prompted by the pop up screen.

No response to TEI requests - Slot=<slot #> Port=<port #> Ces=<communication endpoint suffix> TEI configuration mismatch between the system and the switch for the indicated line. The configuration of the system or of the switch should be corrected.

520 CyberSWITCH

Page 520
Image 520
Enterasys Networks CSX6000, CSX5500 Network sent Cause Spid not supported slot #, port #, No Active Calls Active Sites