USER’S GUIDE

AppleTalk successfully initialized on WAN port with address <AppleTalk address>.

This message is posted when the specified AppleTalk WAN port has initialized successfully.

Attempted to start timer for inactive Signaling Session.

Attempted to stop timer for inactive Signaling Session.

Attempted to use session with no event handler.

An error has been detected in the R2 signaling procedure, and will typically result in a failed call. The error was due to unrecognizable or incorrect information. If problem persists, contact your Distributor or Customer Support.

Attempting to Autobaud, Press <CR> Many Times, Quickly

The user has requested that the RS 232 port undergo an autobaud procedure, or the RS232 port has not been properly Autobauded.

Attempting to load “<FileName>” for Upgrade

A Reliable Remote Upgrade has taken place. The specified file is now being loaded into memory for verification and subsequent installation into the Flash File System.

Attempt to reinitialize DM card in slot <slot # >

The system is attempting to initialize the Digital Modem card again after a failed attempt. Check the subsequent log messages for the status of the card.

Attempt to initialize unconfigured DM card in slot <slot #>

The system is attempting to initialize a Digital Modem card, with no success. This is likely a configuration problem. Check CFGEDIT setup to ensure that it correctly matches existing hardware.

[AUTH] ACE Client has not been initialized.

The ACE client has not been initialized. No service file exists. Server should be expecting CyberSWITCH client to request node verification. Contact the ACE administrator and request the client to be reinitialized.

[AUTH] ACE Could not create service file.

The CyberSWITCH ACE client was in an initialized state. After receiving service information from the ACE server a local file create error occurred while attempting to save the information.

[AUTH] ACE Could not synchronize client-server.

During an authentication attempt the client was unable to synchronize with the server and the user was rejected. The server may not be responding to the client.

[AUTH] ACE Could not write service file.

The CyberSWITCH ACE client was in an initialized state. After receiving service information from the ACE server a local file write error occurred while attempting to save the information.

[AUTH] ACE Decryption of server response failed.

Sever response to an ACE client request was received, but could not be decrypted. Verify encryption method configured for server is accurate.

[AUTH] ACE Encryption configured for DES: not supported.

The ACE server is configured for DES encryption. Only SDI encryption is currently supported by the ACE client.

484 CyberSWITCH

Page 484
Image 484
Enterasys Networks CSX6000 Attempting to Autobaud, Press CR Many Times, Quickly, Attempting to load FileName for Upgrade