Enterasys Networks CSX7000, CSX5500, CSX6000 manual Configuring Lines Using Cfgedit

Models: CSX7000 CSX6000 CSX5500

1 729
Download 729 pages 41.51 Kb
Page 119
Image 119

CONFIGURING RESOURCES AND LINES

Lines

a three card maximum for DM-24s or DM-30s. These cards may also be combined (for example, a DM-8 along with two DM-24s), as long as you adhere to the lower card maximum per system.

LINES

CONFIGURING LINES

Note: There is a preconfigured serial line named ASYNDMPORT to parallel the preconfigured serial resource (COMMPORT). You may not delete this line; however, you may change the line’s values (including the default mode of operation).

USING CFGEDIT

To configure lines, select Data Lines from the Physical Resources menu. Follow instructions for the type of line you are configuring:

CONFIGURING A LINE FOR A BRI RESOURCE

1.Enter the line name.

2.Select the line’s slot and port combination.

3.Choose either a point-to-point or a point-multipoint interface type.

4.If you select a line interface type of point-multipoint, you will need to choose one of the following call screening methods: none, subaddress, or telephone number. If you choose the subaddress screening method, you must configure a subaddress. Refer to Configuring a Subaddress.

5.Add the necessary data links.

a.Select Automatic TEI Negotiation UNLESS this is a point-to-point NTT line.

b.If you need to assign a TEI Negotiation value, the default value of 0 is normally correct.

c.Only if you plan on using X.25 over the D-Channel on this line, answer yes to the following prompt:

Will this Data Link support X.25 communications (Y/N)? [default N]

6.If the line uses a NI-1 or a DMS-100 switch type, you must also enter the following:

a.SPID(s) - supplied by your carrier

b.Directory Number(s) associated with the SPID(s) - supplied by your carrier

c.Number of digits to verify.

CONFIGURING A LINE FOR A PRI RESOURCE

1.Enter the line name.

2.Select the line’s slot and port combination.