SYSTEM MESSAGES

System Message Summary

Data link test successful: DSL <port # >, CES 1

This message applies for 1TR6 BRI only. If Layer 1 is established, a test will be done to determine if the data link can be established. This message indicates successful test results.

Data link up: Slot=<slot #> Port=<port #> Ces=<communication endpoint suffix>

The data link on the specified line is active and can be used for establishing switched connections.

DCE Data Rate is invalid on FrStartPVC

The user has configured a data rate which is inconsistent with the application. This can only happen with serial lines such as V.35 where the data rate must be specified in bits-per-second and the configured rate is not valid.

Dedicated connection down: <slot #, port #>

The dedicated connection is down. Switched backup connections will be used, if available. This message will occur if the other system is down, or if the network interface line is not connected, or if the authentication of the remote device failed.

Dedicated connection to device <device name> up: <slot # >,<port # >

The indicated dedicated connection is operational.

[DHCP-P] Failed to close UDP port after terminating last DHCP client

An internal error occurred in the DHCP Proxy Client. When all DHCP client invocations are terminated, the UDP ports used by the DHCP Proxy Client should be closed. Contact your Distributor or Customer Support.

[DHCP-P] Failed to close UDP port (x), erc = <y>

This message appears when the DHCP Proxy Client is being disabled from Manage Mode and it encounters an error while trying to close one or both of the UDP ports that it has open. Contact your Distributor or Customer Support.

[DHCP-P] Failed to de-register with the IP Address Pool Manager, erc = <x>

This message indicates that a failure was encountered by the DHCP Proxy Client while it was being disabled. It was unsuccessful in its attempt to de-register as a provider of “DHCP” addresses for the IP Address Pool. Contact your Distributor or Customer Support.

[DHCP-P] Failed to open UDP port for first DHCP client

An internal error occurred in the DHCP Proxy Client. When the first DHCP client invocation starts, the UDP ports used by the DHCP Proxy Client should open. Contact your Distributor or Customer Support.

[DHCP-P] Failed to open UDP port (x), erc = <y>

This message appears when the DHCP Proxy Client is being enabled and it encounters an error while trying to open one or both of the UDP ports that it requires for operation. Contact your Distributor or Customer Support.

[DHCP-P] Failed to register with the IP Address Pool Manager, erc = <x>

This message indicates that a failure was encountered by the DHCP Proxy Client while it was being enabled. It was unsuccessful in its attempt to register as a provider of “DHCP” addresses for the IP Address Pool. Contact your Distributor or Customer Support.