User Level Authentication flag is enabled for Terminal User xxx. Setting flag to disabled.

The device definition for xxx should have User Level Authentication disabled.

These two messages are displayed together. In device entries for terminal server connections, user- level authentication should not be enabled. In the event the CyberSWITCH finds an enabled condition, it will disable the pertinent flag for the duration of the call only. To avoid this situation permanently, disable the user level authentication flag in device entries for all terminal server connections.

Waiting for WAN card in slot <slot #> to complete initialization

Download process update for WAN card in slot <slot #>.

WAN card in slot <slot # > signals it is operational

Download process update that indicates that WAN card in slot <slot #> is now operational.

WAN Port is now in the Forwarding state

WAN port connections used by the bridge are now entering the specified state.

WAN Port is now in the <new state> state

The WAN connection port used by the bridge is entering the specified new state.

WAN: RBS Not Available on this card.

A RBS debugging command was attempted on a PRI card that is not configured for RBS. Check the card configuration and ensure you have the proper type of card.

WAN: Verbose Messaging Not Available on this card.

WAN: RBS Not Available on this card.

A RBS debugging command was attempted on a PRI card that is not configured for RBS. Check the card configuration and ensure you have the proper type of card.

Watchdog timeout detected on DM board in slot <slot # >

The Digital Modem card in the specified slot is not functioning properly. Check the board’s configuration in CFGEDIT, reseat the board in its ISA slot, and check any MVIP bus cabling. If everything seems in order and the problem persists, contact your Distributor or Customer Support.

Watchdog timeout detected on WAN board ’x’

The system has detected that the indicated adapter has failed. This is a fatal condition and will cause the card to be reset. Verify the settings on the adapter. If theses are all correct and the problem persists, the indicated adapter card may be faulty. Contact your Distributor or Customer Support.

The following messages are reported when a remote X.25 device's facilities do not match with those configured locally:

X25 facilities error, facilities not allowed in PVC

A facility is configured, for example call deflection, which is not allowed in a PVC. Check your PVC configuration.

X25 facilities error, fast select with restriction on response was required

The fast select with restriction on response is required. Verify that fast select is enabled by both DTE’s and the service provider.