ACCESSING THE CYBERSWITCH

OVERVIEW

This chapter describes accessing your CyberSWITCH, which includes:

making proper connections

establishing an administration session

accessing Release Notes

MAKING CONNECTIONS

There are a number of ways to make a connection to the system, which include:

direct connection using a keyboard and monitor

null-modem connection using a null-modem cable and a PC with Carbon Copy

remote connection using Telnet

remote connection using a modem, a remote PC, and one of the following:

a.Carbon Copy software

b.PPP Dial-Up Networking software

DIRECT CONNECTION

If you only need to configure or manage the CyberSWITCH in a local environment, the simplest access is through a direct connection. The CyberSWITCH is configured to support a PS/2 or AT- style keyboard and a VGA 15-pin monitor.

Physical Connections:

1.Attach keyboard plug to the keyboard connector located on the back of the CyberSWITCH.

2.Attach monitor cable to the local monitor port located on the back of the CyberSWITCH.

Note: The CSX7000 uses a breakout box for these connections. Refer to the Local Console Connection description in the CSX7000 Guide. For the location of the keyboard connector and local monitor port for other platforms, refer to the Hardware Overview chapter.

Powering On:

1.The rear panel on the system provides an AC input power socket. Plug the standard power cord (supplied with the system) into this power socket.

CAUTION:

Some platforms may have a line voltage select switch on the rear panel. If you are using such a platform, make sure that this switch is set for the correct AC input power source. When changing the line voltage select switch, make sure the AC power cord is unplugged.

2.Ensure that the POWER-ON button on the CyberSWITCH is in the OFF position.

3.Ensure that the monitor and keyboard are connected to the proper connectors at the rear panel.

4.Plug the power cord into a grounded electrical outlet.

5.Plug the monitor power cord into a proper electrical outlet.