SYSTEM MESSAGES

System Message Summary

Bridge is operating in RESTRICTED mode

Bridge is operating in UNRESTRICTED mode

One of the above messages will be displayed to indicate the configured Bridge mode of operation.

Calculating CRC’s.....

An X-Modem transfer has been completed and the received data is being checked for integrity.

Callback type <call back type ID> is not currently supported.

During callback negotiation between the CyberSWITCH and the remote device, an unsupported type of callback was received.

Call control detected near end problem - Slot=<slot #> Port=<port #>

The system detected a problem when initiating a call over the indicated line. The call will be retried over a different line if possible.

Call_ID in use in HOST_CALL_REQUEST

An error has been detected in the R2 or RBS signaling procedure, which typically results in a failed call. Contact your Distributor or Customer Support.

Calling Line ID Failure, Duplicate ID - <calling line Id>

A call has come in for a device that is using Calling Line Id (CLID) as the only authentication method, and the given CLID is not unique across all devices.

Calling Line ID Security Failure <calling line Id>

The system has rejected a device due to a mismatch between the Calling Line Id presented by the caller and the Calling Line Id in the on-node device database or obtained via an off-node authentication server such as RADIUS.

Calling Line ID Security Failure <calling line Id>, Device: <device name>

The system has rejected a device due to a mismatch between the Calling Line Id presented by the caller and the Calling Line Id in the on-node device database or obtained via an off-node authentication server such as RADIUS. The device’s name is also contained within the database.

Calling Line ID Security Failure - off-node authentication server not supported

The system authentication type is configured to obtain device information off-node, for example from a RADIUS server; however, such transactions are not yet supported when Calling Line Id Security is enabled.

Call Rejected, Maximum Bandwidth already in place to Device Id <device Id>

An incoming call was rejected because the Maximum Data Rate parameter was exceeded for the indicated device. The Maximum Data Rate parameter can be configured for PPP devices under the configuration utility CFGEDIT or through the Manage Mode.

Call Rejected, No Called TN IE

The switch did not deliver an Information Element for the call. This problem normally occurs if you are connected to a point-to-point line and have the System configured for a multipoint line. If you are connected to a multipoint line and get this message, call your phone company and report the problem.

Call Restrictions have been disabled by user command

The user has disabled Call Restrictions via the callrest off Dynamic Management command.

Central Site Remote Access Switch 489

Page 489
Image 489
Enterasys Networks CSX5500, CSX6000, CSX7000 Calculating CRC’s, Callback type call back type ID is not currently supported