HARDWARE OVERVIEW

System Platforms

6.Insert the clean and dry air filter back into its slot behind the chassis front. Tilt the filter forward into place until it is flush against the chassis front panel.

7.Reinstall the two retaining screws along the top lip of the chassis.

8.Replace the system’s top cover.

9.Reconnect the power cord and power up the system.

PLATFORM CHARACTERISTICS

 

 

Physical Characteristics

 

 

Height:

178 mm (7.0 in)

 

Width:

432 mm (17.0 in)

 

Depth:

452 mm (17.8 in)

 

Weight:

22 kg maximum (44 lb. maximum)

Environmental Characteristics

0° to 50° C (41° to 122° F)

Operating Temp:

Operating Humidity:

20 - 85% non-condensing

Operating Altitude:

3048 m maximum (10,000 ft maximum)

Non-operating Shock:

40 G, 11 ms 1/2 sine wave

Storage Temperature:

-25° to +70° C (-13° to 158° F)

Electrical AC Power Input

 

 

Voltage:

90 - 135 V

Current:5 A

Voltage:

180 - 265 V

Current:4 A

Frequency:

47 - 63 Hz

 

Regulatory Compliance

 

 

Meets or exceeds the following:

 

Safety:

UL 1950, CSA C22.2 No. 950, EN 60950, IEC 950,

 

and 72/23/EEC

 

EMI:

FCC Part 15, EN 55022, CSA 108.8, EN 50082-1,

 

VCCI V-3, and 89/336/EEC

Central Site Remote Access Switch 57

Page 57
Image 57
Enterasys Networks CSX5500, CSX6000, CSX7000 manual Emi