USER’S GUIDE

Received charge amount - <charge amount>

The system has received an advice of charge from the network for the call just disconnected. The charge for this call is indicated in the charge amount parameter.

Received CLLM while PVC for DLCI <dlci index> in unexpected state <state>

A CLLM message was received indicating that a network condition should be expected for the PVC associated with the indicated DLCI. However, this PVC is in the indicated state and as such is already acting on a previous network condition notification.

Remote peer ID discrepancy

The On-node Device Table and the remote end of the connection disagree on the identity of the remote end. Check configuration, and then reboot the remote device. If problem persists, contact your Distributor or Customer Support.

Replace Lithium Battery: Contact your Representative

If this message is displayed in the log messages, contact your Distributor or Customer Support before you power off your system.

Requested channel not available - <slot #, port # >

The system has attempted a call using a channel on the indicated line that was not available. The call will be retried over a different line if possible.

Reserved signal

This message is informational only and is used to indicate additional details on the <signal value> received in the “call progress” information message.

Resmem_gettotal: Enabled size <size>, greater than Checksize <size> for <sub name> Internal error that should be reported to Customer Support.

ResMem_Malloc failure for subsystem <sub name>

(size=<size>, type=<type>, class=<class>, ra=<hex return address>)

ResMem_Malloc Size <size> too large for subsystem <sub name> (type=<type>, class=<class> ra=<hex return address>)

ResMem_Malloc Device not registered (ra=<hex return address>) ResMem_Obtainable Device not registered (ra=<hex return address>)

Any of the above three messages indicate that an internal error has occurred that should be reported to Customer Support. The system will restart when this error occurs.

Retrying download of DM card in slot <slot# > in <x> seconds

The system has failed on previous attempts to initialize the Digital Modem card. The system will retry a specific number of times before logging a failure message. Check the hardware and software configuration, reseat the card in its ISA slot, and/or check the MVIP cabling. If the problem persists, contact your Distributor or Customer Support.

Rx Channel Inactivity Detected

No keep-alive frames have been received over an active connection to a remote system. This indicates that the connection or the remote node has failed (or been powered-off) without an indication of the failure from the network. If the event continues, contact your Distributor or Customer Support.

526 CyberSWITCH

Page 526
Image 526
Enterasys Networks CSX6000, CSX5500 manual Received charge amount charge amount, Remote peer ID discrepancy, Reserved signal